PERBEDAAN KADAR SGOT PADA SERUM SEGAR, SERUM TUNDA 4 JAM PADA SUHU RUANG, DAN SERUM TUNDA 5 JAM PADA 4 – 6 ºC

Putri, Brilliana Defany (2019) PERBEDAAN KADAR SGOT PADA SERUM SEGAR, SERUM TUNDA 4 JAM PADA SUHU RUANG, DAN SERUM TUNDA 5 JAM PADA 4 – 6 ºC. Skripsi thesis, Universitas Setia Budi.

[img] Text
1. INTISARI DAN ABSTRAK.pdf

Download (217kB)
[img] Text
2. FORM PUBLIKASI.pdf

Download (173kB)
[img] Text
3. cover - bab 1.pdf

Download (548kB)
[img] Text
4. BAB 2.pdf
Restricted to Repository staff only

Download (216kB) | Request a copy
[img] Text
5. BAB 3.pdf
Restricted to Repository staff only

Download (244kB) | Request a copy
[img] Text
6. bab 4.pdf
Restricted to Repository staff only

Download (199kB) | Request a copy
[img] Text
7. BAB 5 - LAMPIRAN.pdf

Download (2MB)

Abstract

Serum Glutamic Oxaloacetic Transminase (SGOT) is one of the ingredients in the serum. Occasionally, the sample is not immediately examined and stored. This is one of the factors that influences the results of the examination. Serum can be stored at room temperature for 4 hours, if the test is delayed more than 4 hours the serum must be stored at 4-6º C. The objective of this research is to find out differences in SGOT levels in fresh serum, 4 hours delay at room temperature, and 5 hours delay at 4 - 6° C. This research used an observational analytic research design cross sectional approach. The research subjects were 33 samples. Normality test was conducted with Shapiro-Wilk with significance of p> 0.05 and Wilcoxon test with significance of p <0.05. From this research, we found out that fresh serum SGOT levels and 4 hours delay at room temperature is p= 0.170 (p> 0.05), fresh serum SGOT levels and 5 hours delay at 4 - 6° C is p= 0.160 (p > 0.05), serum SGOT levels and 4 hours delay at room temperature and 5 hours delay at 4 - 6° C is p = 0.712 (p > 0.05). It can be concluded that there is no difference in fresh serum SGOT levels and 4 hours delay at room temperature, also there is no difference in fresh serum SGOT levels and 5 hours delay at 4 - 6° C. Moreover, there is no difference in serum SGOT levels and 4 hours delay at room temperature and 5 hours delay at 4 - 6° C. Keywords: SGOT levels, fresh serum, 4 hour delay serum at room temperature, 5 hour delay serum at 4 - 6° C

Item Type: Thesis (Skripsi)
Uncontrolled Keywords: SGOT levels, fresh serum, 4 hour delay serum at room temperature, 5 hour delay serum at 4 - 6° C
Subjects: Q Science > QR Microbiology
Divisions: Fakultas Ilmu Kesehatan > Prodi D4 Analis Kesehatan
Depositing User: Tifany Nur Arfiana
Date Deposited: 15 Oct 2019 08:46
Last Modified: 15 Oct 2019 08:46
URI: http://repo.setiabudi.ac.id/id/eprint/3240

Actions (login required)

View Item View Item