ANALISIS QUALITY CONTROL ALAT HEMATOLOGY ANALYZER di LABORATORIUM HEMATOLOGI UNIVERSITAS SETIA BUDI

Haryunta, Anisa (2023) ANALISIS QUALITY CONTROL ALAT HEMATOLOGY ANALYZER di LABORATORIUM HEMATOLOGI UNIVERSITAS SETIA BUDI. Karya Tulis Ilmiah thesis, Universitas Setia Budi.

[img] Text
form publikasi.pdf

Download (114kB)
[img] Text
INTISARI dan ABSTRACT.pdf

Download (76kB)
[img] Text
COVER - BAB I.pdf

Download (1MB)
[img] Text
BAB II.pdf

Download (460kB)
[img] Text
BAB III.pdf

Download (140kB)
[img] Text
BAB IV.pdf
Restricted to Repository staff only

Download (46kB)
[img] Text
BAB V.pdf
Restricted to Repository staff only

Download (14kB)
[img] Text
DAFTAR PUSTAKA.pdf

Download (155kB)
[img] Text
LAMPIRAN.pdf
Restricted to Repository staff only

Download (70kB)

Abstract

Anisa Haryunta, 2023. Quality Control Analysis of the Hematology Analyzer Tool at the Hematology Laboratory of Setia Budi University, "Scientific Writing", D3 Health Analyst Study Program, Faculty of Health Sciences, Setia Budi University. Laboratory examination consists of a series of related processes. The examination process in the laboratory is divided into 3 stages, namely the pre-analytical, analytical and post-analytical stages. Quality control is a process within a procedure that is used to evaluate the testing process with the aim of ensuring that the quality system is running properly and is carried out to guarantee the results of laboratory tests, identify and minimize deviations and identify sources of deviations. Aims to find out how to analyze the quality control of the hematology analyzer in the Setia Budi University laboratory. The method used was a descriptive research design with a cross�sectional approach, with a population and sample of quality control results then analyzed into the Westgrad Multirule and the Levey-Jenning chart. HGB examination results (CV = 1.03% and d% = 0.49%), on HCT examination (CV = 3.53% and d% = 0.86%), on RBC examination (CV = 3.40% and d% = 0.33%), on WBC examination (CV = 2.57% and d% = 0.17%) and on PLT examination (CV = 4.07% and d% = 0.20%). The results show that the TE(%) value is greater than the TEA(%) value for the HGB, WBC and PLT parameters, while for the HCT and RBC parameters the TE(%) value is smaller than the TEA(%) value. In the Westgrad Multirules analysis, there were no deviations in the HGB, while in the RBC, WBC and PLT examination parameters it was found that several parameters were within the 12S warning rule and the RBC HCT was found to be in the 41S and 10x rejection rules. The Medonic M-Series 16M Hematology Analyzer Tool at the Setia Budi University Hematology Laboratory, the tool is imprecise and inaccurate, so it is necessary to carry out equipment maintenance to ensure valid examination results and improve examination quality

Item Type: Thesis (Karya Tulis Ilmiah)
Uncontrolled Keywords: Quality Control, Hematology Analyzer
Subjects: R Medicine > RS Pharmacy and materia medica
Divisions: Fakultas Ilmu Kesehatan > Prodi D3 Analis Kesehatan
Depositing User: USB
Date Deposited: 29 Feb 2024 06:09
Last Modified: 29 Feb 2024 06:09
URI: http://repo.setiabudi.ac.id/id/eprint/6051

Actions (login required)

View Item View Item