ANALISIS PEMANTAPAN MUTU INTERNAL PEMERIKSAAN TROMBOSIT DENGAN ALAT MINDRAY BC-20s DI LABORATORIUM HoREX BAUCAU TIMOR-LESTE

SARMENTO, JOSE MARTINS (2023) ANALISIS PEMANTAPAN MUTU INTERNAL PEMERIKSAAN TROMBOSIT DENGAN ALAT MINDRAY BC-20s DI LABORATORIUM HoREX BAUCAU TIMOR-LESTE. Skripsi thesis, Universitas Setia Budi.

[img] Text
INTISARI ABSTRACT.pdf

Download (211kB)
[img] Text
publikasi.pdf

Download (384kB)
[img] Text
jose surat 22 agustus.pdf

Download (39kB)
[img] Text
COVER - BAB 1.pdf

Download (1MB)
[img] Text
BAB 2.pdf

Download (611kB)
[img] Text
BAB 3.pdf
Restricted to Repository staff only

Download (223kB)
[img] Text
BAB 4.pdf
Restricted to Repository staff only

Download (37kB)
[img] Text
BAB 5.pdf
Restricted to Repository staff only

Download (131kB)
[img] Text
DAFTAR PUSTAKA.pdf

Download (17kB)
[img] Text
LAMPIRAN.pdf
Restricted to Repository staff only

Download (90kB)

Abstract

Martins, SJ. Analysis of Internal Quality Assurance of Platelet Examination with the Mindray Bc-20s Tool at the Horex Baucau Laboratory, Timor-Leste. Bachelor of Medical Laboratory Technology, Faculty of Health Sciences, Setia Budi University Examination of platelets in the HoREX laboratory is an examination with high presentation so it is necessary to carry out an internal quality assurance analysis. The aim of this study was to analyze the accuracy and precision of platelet examination with the BC-20s mindray tool in the HoREX laboratory. The research method used is descriptive. The data used is secondary data from daily quality control of platelet examination in March 2023 by means of the data obtained and then analyzed using the Microsoft Excel application. Statistical test results obtained low level accuracy of 14.16%, normal level of 6.435%, and high level of 6.770%, low level precision of 13.78%, normal level of 18.73% and high level of 2.75% bias value at low level 0.28%, normal 0.01%, high level 0.03%, and the total error level low is 28.43%, normal level is 12.08%, and high level is 13.32%. The data obtained shows that the hematology analyzer mindray BC-20s has poor accuracy and precision. Levvey-Jennings chart evaluation of platelet control materials at low levels occurs violations of the Westgard Multirule 10-x, and 1-2s rules, for normal control levels violations of the Westgard Multirule 12-x rules . The results of the high level Levvey-Jennings graph show violations of the 10-x multirule rule. The graph shows systematic errors and trends at the three levels of control materials.

Item Type: Thesis (Skripsi)
Uncontrolled Keywords: Trombosit Quality Control ,Mindray BC-20s. Platelet Quality Control, Mindray BC-20s.
Subjects: L Education > L Education (General)
Q Science > Q Science (General)
Divisions: Fakultas Ilmu Kesehatan > Prodi D4 Analis Kesehatan