BARROS, ANASTÁCIA GOMES (2023) PERBANDINGAN HASIL PEMERIKSAAN MIKROSKOPIS DAN GENEXPERT PADA SPESIMEN SPUTUM SUSPEK TB PARU DI PUSKESMAS ATSABE, TIMOR-LESTE. Skripsi thesis, Universitas Setia Budi.
Text
INTISARI ABSTRACT.pdf Download (101kB) |
|
Text
FORM PUBLIKASI ANASTACIA.pdf Download (383kB) |
|
Text
anastasia hasi_ 21 agustus.pdf Download (39kB) |
|
Text
COVER - BAB 1.pdf Download (760kB) |
|
Text
BAB 2.pdf Download (283kB) |
|
Text
BAB 3.pdf Restricted to Repository staff only Download (126kB) |
|
Text
BAB 4.pdf Restricted to Repository staff only Download (231kB) |
|
Text
BAB 5.pdf Restricted to Repository staff only Download (96kB) |
|
Text
DAFTAR PUSTAKA.pdf Download (319kB) |
|
Text
LAMPIRAN.pdf Restricted to Repository staff only Download (280kB) |
Abstract
Barros, A.G. 2023.COMPARISON OF THE RESULTS OF MICROSCOPIC EXAMINATION AND GENE EXPERT PADA SPECIMEN SPUTUM SUSPEC TB LUNGS AT ATSABE HEALTH CENTER, TIMOR-LESTE.Thesis. D4 Medical Laboratory Technology Study Program, Faculty of Health Sciences, Setia Budi University, Surakarta Tuberculosis lung disease is an infectious disease caused by bacteria Mycobacterium tuberculosis, with the most location in the lungs. Timor-Leste recorded an increasing number of prevalence tuberculosis from 490 per 1000 population to 508, increased mortality from 100 to 106 sufferers tuberculosis. The research objective is to find out the comparison of examination results Mycobacterium tuberculosis lung based GeneXpert and Microscopy of sputum specimens. This type of research uses an observational analytic research design approach cross sectional. This research was conducted at the Atsabe Community Health Center Laboratory. This research uses secondary data, data is collected starting from the period January-July 2022. The population of this study is all suspected data tuberculosis lungs who carry out laboratory examinations with techniques Total sampling as many as 30 suspects tuberculosis lungs. The data collected was processed using a test Who squares. Negative result on microscopic examination method Zhiel Neelsen as many as 27 (90%) and positive results as much as 3 (10%), examination data Real Time GeneXpert obtained MTB Not Detected as many as 17 (56%) and results MTB Detected as many as 13 (43.3%). Based on the Asymp.sig output value. (2- sided) on the test pearson Chi Square is 0.037 <0.05, it is concluded by the method Real-Time GeneXpert has a higher sensitivity compared to the staining method Zhiel Neelsen due to inspection GeneXpert able to detect 10 MTB Detected at 27 BTA negative sputum specimen
Item Type: | Thesis (Skripsi) |
---|---|
Uncontrolled Keywords: | Mikroskop, GeneXpert, Tuberculosis Paru, Microscope, GeneXpert, Tuberculosis Lungs. |
Subjects: | Q Science > Q Science (General) |
Divisions: | Fakultas Ilmu Kesehatan > Prodi D4 Analis Kesehatan |
Depositing User: | USB |
Date Deposited: | 08 Oct 2024 03:19 |
Last Modified: | 08 Oct 2024 03:19 |
URI: | http://repo.setiabudi.ac.id/id/eprint/6385 |
Actions (login required)
View Item |